Control Chief TM6000 Manual del operador Pagina 97

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 201
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 96
TM 10-3930-660-10
0010 00-1
TROUBLESHOOTING PROCEDURES 0010 00
Table 1. Troubleshooting Procedures.
MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION
1. Engine Will Not Crank. Check to see if range select
control lever is in the Neutral
“N” position.
Move range select control lever
to “N” position (WP 0004 00).
Check for loose or disconnected
battery cables.
Notify Maintenance.
2. Engine Cranks But Will Not Start. 1. Check to see if the auxiliary
fuel shut-off switch is in the
OFF position.
Move the auxiliary fuel shut-off
switch to the ON position (WP
0004 00).
2. Check to see if fuel tank is
empty.
Fill fuel tank (WP 0021 00).
3. Check the ambient
temperature.
Use the engine primer button in
extreme cold temperature to start
the engine (WP 0006 00).
4. Check the fuel/water separator
for water.
Drain the fuel/water separator
(WP 0019 00).
5. Check to see if any fuel lines
are damaged.
Notify Maintenance.
3. Engine Misfires or Runs Rough. 1. Check to see if fuel tank is low
or empty.
Fill fuel tank (WP 0021 00).
2. Check to see if any moisture is
present in fuel/water separator.
Drain the fuel/water separator
(WP 0019 00).
3. Check for black or gray
exhaust smoke. Plugged or
dirty intake system.
Clean or replace air filters (WP
0017 00).
4. Check for white or blue smoke.
Indicates engine is cold.
Allow engine to warm up.
5. Check for leaks in fuel lines
and injectors.
Notify Maintenance.
4. Low Engine Power. 1. Check air filter restriction
indicator.
Clean the air filter (WP 0017 00).
2. Check the exhaust pipe for
obstruction.
Remove any obstructions.
3. Check for high engine oil
level.
Notify Maintenance if oil level
is high.
Vista de pagina 96