TM 10-3930-660-10
0012 00-17
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
45 Weekly Batteries
WARNING
• To avoid injury, eye protection and acid-resistant gloves
must be worn when working around batteries. Do not
smoke, use open flame, make sparks or create other igni-
tion sources around batteries, If a battery is giving off
gases, it can explode and cause injury to personnel.
Remove all jewelry such as rings, ID tags, watches, and
bracelets. If jewelry or a tool contacts a battery terminal, a
direct short will result in instant heating, damage to equip-
ment, and injury to personnel.
• Sulfuric acid contained in batteries can cause serious burns.
If battery corrosion or electrolyte makes contact with skin,
eyes or clothing, take immediate action to stop the corro-
sive burning effects. Failure to follow these procedure may
result in death or serious injury to personnel.
CAUTION
To reduce battery damage, check battery compartment for
corrosion (greenish/white powder) and do NOT jerk or pull
on battery cables during visual inspection.
a. Access batteries by removing
battery box cover.
b. Check battery hold-down for
looseness or damage.
Hold-down is loose or damaged.
c. Inspect batteries for a cracked
case and evidence of leaking.
Battery case is cracked or leaks
are evident.